| MODEL |
RANGE
In Liquids |
RESOLUTION |
TRI-CLAMP
Fitting |
R3-50S
3-wire, DC
|
*
to 50'
(* to 15m) |
0.22"
(5.7mm) |
2.0" |
R3-100S
3-wire, DC |
*
to 100'
(* to 30m) |
0.44"
(11mm) |
2.0" |
R4-50S
4-wire, AC |
*
to 50'
(* to 15m) |
0.22"
(5.7mm) |
2.0" |
R4-100S
4-wire, AC |
*
to 100'
(* to 30m) |
0.44"
(11mm) |
2.0" |
| * Minimum distance starts at the lower tip
of the antenna. |
Click here for standard Radar Level Sensor models. |
|
| Features: |
| • |
Programmable
and push-button calibration |
| • |
Output:
4-20 mA/20-4 mA (isolated on 4-wire models
only) |
| • |
PLC
compatible (Modbus RTU) |
| • |
3-
or 4-wire operation |
|
|
| Applications: |
| • |
Food
and beverage |
| • |
Water |
| • |
Pharmaceutical |
|
|
| Specifications: |
| Electrical: |
| |
Power |
AC:
115 VAC, 60 Hz or 230 VAC, 50 Hz (± 20%)
1.7 VA
DC: 12 to 30 VDC, 0.07 Amps max. @ 24 VDC
R
load = (Vs–6)/24
mA |
| Output |
4-20
mA or 20-4 mA, 6.1 uA resolution; 750 ohms (isolated
on 4-wire models only)
RS232 or RS485 communications port |
 |
| Operational: |
| |
Operation |
Pulse
radar |
| Accuracy |
± 0.1%
of maximum range in lab using 4-20 mA current output
± 0.25% of maximum range (typically in field) |
| Frequency |
5.8
GHz or 6.3 GHz |
| Loss
of Echo Hold |
30 seconds, 22 mA output |
| Transmitter
Power |
50 uW average |
| Calibration |
Programmable
via communications port or push button |
| Diagnostics (Echo Profile) |
Via
communications port |
| Antenna
Dielectric Road |
Polypropylene
(standard), PTFE (optional) |
| Decoupler |
Polypropylene
(standard), PTFE (optional) |
 |
| Environmental: |
| |
Operating
Temperature Range |
-40°C
to 60°C (-40°F to 140°F) |
| Installation
Category |
Class
II |
| Approvals |
FCC
Part 15 — low-power communication device |
 |
| Mechanical: |
| |
Conduit
Entry |
1/2" NPT
standard |
| Enclosure |
Aluminum
(standard) or stainless steel 316L (optional) |
| Ingress
Protection |
NEMA
4 (IP65) |
| Mounting
Options |
Swivel
socket (galvanized steel); PVC flange with 3"-8
NPT thread |
 |
| Process: |
| |
Temperature |
PTFE
Rod : -40°C to 204°C (-40°F
to 400°F) with tri-clamp |
| Material
Dielectric |
Class
II |
| Pressure |
1-10
BAR, 15-150 PSI |
 |
| Approvals: |
| |
CE approval on 5.8 GHz
models |
| Consult
factory for others |
|
| R
Series Radar Level Sensors: |
| MODEL |
VOLTS |
DWG
NO. |
HOUSING
MATL.
STD. (OPTIONAL) |
COMM.
PORT |
RANGE |
RESOLUTION |
MOUNTING |
OPERATING
FREQUENCY |
BEAM
ANGLE |
APPROVALS |
| (FEET) |
(M) |
(INCHES) |
(MM) |
| R3-50C2 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R3-50C4 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R3-50SC2 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R3-50SC4 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-50C2 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-50C4 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-50SC2 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-50SC4 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-50C2 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-50C4 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-50SC2 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-50SC4 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R3-50C2-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R3-50C4-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R3-50SC2-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R3-50SC4-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-50C2-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-50C4-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-50SC2-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-50SC4-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-50C2-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-50C4-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-50SC2-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-50SC4-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
50 |
15.2 |
0.22 |
5.7 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R3-100C2 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R3-100C4 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R3-100SC2 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R3-100SC4 |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-100C2 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-100C4 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-100SC2 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-100SC4 |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-100C2 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-100C4 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
6.3
GHz |
20° |
J |
| R4-100SC2 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R4-100SC4 |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
6.3
GHz |
20° |
J |
| R3-100C2-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R3-100C4-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R3-100SC2-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R3-100SC4-E |
24
DC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-100C2-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-100C4-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-100SC2-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-100SC4-E |
110
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-100C2-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-100C4-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" NPT |
5.8
GHz |
20° |
C,J |
| R4-100SC2-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS232 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
| R4-100SC4-E |
230
AC |
NC-10 |
Aluminum
(316 SS) |
RS485 |
100 |
30.5 |
0.44 |
11.0 |
2.0" Tri-Clamp |
5.8
GHz |
20° |
C,J |
|
| All
the above models are available with AC or DC power
and in sanitary (food-grade)
designs (sanitary models have an S in the model
number). |
|
| |
| All
specifications are subject to change without notice. |
| [Top
of page | Non-Contact Sensors | Level
Switches & Sensors] |
|