| MAD4500 & MAD4510 Specifications: |
| Performance @ 25°C (77°F): |
| |
Accuracy* |
< ±0.25% BFSL |
| Stability (1 year) |
±0.25% FS, typical |
| Over-Range Protection |
2X Rated Pressure |
| Burst Pressure |
5X or 1,250 PSI (whichever is less) |
| Pressure Cycles |
> 50 Million |
| * Accuracy includes non-linearity, hysteresis & non-repeatability |
 |
| Environmental: |
| |
Operating Temperature |
-40°F to 185°F (-40°C to 85°C) |
| Storage Temperature |
-40°F to 212°F (-40°C to 100°C) |
| Compensated Range |
30°F to 130°F (0°C to 55°C) |
| TC Zero |
< ±1.5% of FS |
| TC Span |
< ±1.5% of FS |
| Shock |
100G, 11 msec, 1/2 sine |
| Vibration |
10G peak, 20 to 2000 Hz |
| EMI/RFI Protection |
Yes |
| Rating |
IP-68 |
| Cable Length (recommended max.) |
1-5 V < 35’; 4-20 mA, 500’ |
 |
| Electrical: |
| Output |
4-20 mA |
1-5 VDC |
| Excitation |
10-28 VDC |
10-28 VDC |
| Output Impedance |
> 10k Ohms |
< 100 Ohms, nominal |
| Current Consumption |
20 mA, typical |
< 10 mA |
| Bandwidth (-3 dB) |
DC to 250 Hz |
DC to 1 kHz |
| Output Noise |
N/A |
< 2 mV RMS |
| Zero Offset |
< ±1% of FS |
< ±1% of FS |
| Span Tolerance |
< ±2% of FS |
< ±1.5% of FS |
| Output Load |
0-800 Ohms @ 10-28 VDC |
10k Ohms, min. |
| Reverse Polarity Protection |
Yes |
Yes |
|
 |
| Pressure Ranges: |
| MAD4500 |
| Gage PSIG |
BAR |
Pressure Range Code |
| 0-100 |
6.89 |
00100 |
| 0-50 |
3.45 |
00050 |
| 0-30 |
2.07 |
00030 |
| 0-20 |
1.38 |
00020 |
| MAD4510 |
| Gage PSIG |
BAR |
Pressure Range Code |
| 0-15 |
1.03 |
00015 |
| 0-10 |
0.69 |
00010 |
| 0-7.5 |
0.52 |
00208** |
| 0-5 |
0.35 |
00005 |
| 0-2.5 |
0.17 |
00069 |
|
Typical ranges. All ranges between 0-15 PSI and 0-100 PSI are available. Please consult factory.
** Must be ordered in inches of H2O. |
 |
 |
 |
| Intrinsically safe installations require approved barriers. Refer to the PR Series Reference section for further details. |
 |
 |
| Note: Sensors are vented to atmosphere through surface end of cables. |
| |